هوالرزاق


دسته بندی

ماژول ترموستات دیجیتال XH-W1313 دارای نمایشگر و کلیدهای کنترلی

کد انبار : 3379-78-5384
مدل کالا:XH-W1313   جستارش:
موجودی: در حال حاضر موجود نمی باشد. مشاهده وضعیت کالا
[ برای اطلاع از موجودی این کالا در آینده، بر روی دکمه "اضافه به سبد خرید" کلیک کنید]
قیمت:
38,870تومان

تعداد: - +
   - یا -   

ماژول ترموستات دیجیتال XH-W1313 دارای نمایشگر و کلیدهای کنترلی

performance :
The controller uses industrial microcomputer control system, stable performance is simple. Temperature detection using K -type thermocouple, with easy installation, high temperature, long life and other advantages. This product unique Chinese display panel, mode and working status real-time visible.

product parameters:
Product Name: Digital Thermostat
Specifications Model: XH-W1313
Input voltage: DC12V
Motherboard power consumption: < 3W
Temperature range: -30 ~ 999 ℃
Measurement input: K type thermocouple
Temperature measurement accuracy: ± 1 ℃
Output type: one relay output
Display window: 38 * 20mm
Overall size: 79 * 51 * 27mm

lights and fault code
The main window displays the current real time temperature when the power is turned on
Ent: confirm button, press once to determine the set value, long press to achieve the switch machine.
SET: Set key, press once to enter main menu ( F1-F5 )
" + " Plus key: increase the panel display value
" - " minus key: Decreases the panel display value
LLL / HHH: Sensor or sensor failure not connected
Mode / Cooling: Lit Description The current mode is the cooling mode
Mode / Heating: On Indicates that the current mode is heating mode
Start: On indicates that the output has been started and the relay is closed

Internal set instructions
Press SET display panel Fl-the F5 , can be set for each value of the parameter by a button operation
F1 : Set the desired temperature
F2 : Setting the operating mode H = Heating, C = Cooling [This step is very important].
F3 : hysteresis set, that is, how much effort to work again.
F4 : temperature correction, display value = real-time value + correction value
F5 : high temperature alarm, reach the temperature thermostat will prompt the alarm

Parameter table

menu

Menu description

Predetermined area

Factory setting

F1

set temperature

-50-999 ° C

25

F2

Operating mode

H / C

H

F3

Set hysteresis

1-100

2

F4

Temperature correction

-10.0 ~ + 10.0

0

F5

High temperature alarm

-45-999

OFF

 

 

 

 

 

 

 

 

 

 

 

 

Use method:
1 , set F1 target temperature (stop temperature)
2 , set the F2 mode, H for the heating, C for the cooling
3 , set the hysteresis value, (stop after the number of restart again)

 

 

 

برای درج نظر لطفا وارد حساب کاربری خود در فروشگاه شوید
AftabRayaneh©2017